Freescale Semiconductor /MKE15D7 /TSI0 /GENCS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as GENCS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)STPE 0 (0)STM 0 (RESERVED)RESERVED 0 (RESERVED)RESERVED 0 (0)ESOR 0 (0)ERIE 0 (0)TSIIE 0 (0)TSIEN 0 (SWTS)SWTS 0 (SCNIP)SCNIP 0 (RESERVED)RESERVED 0 (0)OVRF 0 (0)EXTERF 0 (OUTRGF)OUTRGF 0 (EOSF)EOSF 0 (000)PS0 (00000)NSCN0 (RESERVED)RESERVED

ERIE=0, STPE=0, NSCN=00000, PS=000, OVRF=0, EXTERF=0, TSIEN=0, TSIIE=0, STM=0, ESOR=0

Description

General Control and Status Register

Fields

STPE

no description available

0 (0): Disable TSI when MCU goes into low power modes.

1 (1): Allows TSI to continue running in all low power modes.

STM

Scan Trigger Mode. User is allowed to change this bit when TSI is not working in progress.

0 (0): Software trigger scan.

1 (1): Periodical Scan.

RESERVED

Reserved

RESERVED

no description available

ESOR

End-of-Scan or Out-of-Range Interrupt select

0 (0): Out-of-Range interrupt is allowed.

1 (1): End-of-Scan interrupt is allowed.

ERIE

Error Interrupt Enable

0 (0): Interrupt disabled for error.

1 (1): Interrupt enabled for error.

TSIIE

Touch Sensing Input Interrupt Module Enable

0 (0): Interrupt from TSI is disabled.

1 (1): Interrupt from TSI is enabled.

TSIEN

Touch Sensing Input Module Enable

0 (0): Disable

1 (1): Enable

SWTS

Software Trigger Start

SCNIP

Scan In Progress status

RESERVED

no description available

OVRF

Overrun error Flag. This flag is set when a scan trigger occurs while a scan is still in progress. Write “1”, when this flag is set, to clear it…

0 (0): No over run.

1 (1): Over Run occurred.

EXTERF

External Electrode error occurred

0 (0): No short.

1 (1): Short to VDD or VSS was detected on one or more electrodes.

OUTRGF

Out of Range Flag.

EOSF

End of Scan Flag.

PS

Electrode Oscillator prescaler. .

0 (000): Electrode Oscillator Frequency divided by 1

1 (001): Electrode Oscillator Frequency divided by 2

2 (010): Electrode Oscillator Frequency divided by 4

3 (011): Electrode Oscillator Frequency divided by 8

4 (100): Electrode Oscillator Frequency divided by 16

5 (101): Electrode Oscillator Frequency divided by 32

6 (110): Electrode Oscillator Frequency divided by 64

7 (111): Electrode Oscillator Frequency divided by 128

NSCN

Number of Consecutive Scans per Electrode electrode.

0 (00000): Once per electrode

1 (00001): Twice per electrode

2 (00010): 3 times per electrode

3 (00011): 4 times per electrode

4 (00100): 5 times per electrode

5 (00101): 6 times per electrode

6 (00110): 7 times per electrode

7 (00111): 8 times per electrode

8 (01000): 9 times per electrode

9 (01001): 10 times per electrode

10 (01010): 11 times per electrode

11 (01011): 12 times per electrode

12 (01100): 13 times per electrode

13 (01101): 14 times per electrode

14 (01110): 15 times per electrode

15 (01111): 16 times per electrode

16 (10000): 17 times per electrode

17 (10001): 18 times per electrode

18 (10010): 19 times per electrode

19 (10011): 20 times per electrode

20 (10100): 21 times per electrode

21 (10101): 22 times per electrode

22 (10110): 23 times per electrode

23 (10111): 24 times per electrode

24 (11000): 25 times per electrode

25 (11001): 26 times per electrode

26 (11010): 27 times per electrode

27 (11011): 28 times per electrode

28 (11100): 29 times per electrode

29 (11101): 30 times per electrode

30 (11110): 31 times per electrode

31 (11111): 32 times per electrode

RESERVED

no description available