ERIE=0, STPE=0, NSCN=00000, PS=000, OVRF=0, EXTERF=0, TSIEN=0, TSIIE=0, STM=0, ESOR=0
General Control and Status Register
STPE | no description available 0 (0): Disable TSI when MCU goes into low power modes. 1 (1): Allows TSI to continue running in all low power modes. |
STM | Scan Trigger Mode. User is allowed to change this bit when TSI is not working in progress. 0 (0): Software trigger scan. 1 (1): Periodical Scan. |
RESERVED | Reserved |
RESERVED | no description available |
ESOR | End-of-Scan or Out-of-Range Interrupt select 0 (0): Out-of-Range interrupt is allowed. 1 (1): End-of-Scan interrupt is allowed. |
ERIE | Error Interrupt Enable 0 (0): Interrupt disabled for error. 1 (1): Interrupt enabled for error. |
TSIIE | Touch Sensing Input Interrupt Module Enable 0 (0): Interrupt from TSI is disabled. 1 (1): Interrupt from TSI is enabled. |
TSIEN | Touch Sensing Input Module Enable 0 (0): Disable 1 (1): Enable |
SWTS | Software Trigger Start |
SCNIP | Scan In Progress status |
RESERVED | no description available |
OVRF | Overrun error Flag. This flag is set when a scan trigger occurs while a scan is still in progress. Write “1”, when this flag is set, to clear it… 0 (0): No over run. 1 (1): Over Run occurred. |
EXTERF | External Electrode error occurred 0 (0): No short. 1 (1): Short to VDD or VSS was detected on one or more electrodes. |
OUTRGF | Out of Range Flag. |
EOSF | End of Scan Flag. |
PS | Electrode Oscillator prescaler. . 0 (000): Electrode Oscillator Frequency divided by 1 1 (001): Electrode Oscillator Frequency divided by 2 2 (010): Electrode Oscillator Frequency divided by 4 3 (011): Electrode Oscillator Frequency divided by 8 4 (100): Electrode Oscillator Frequency divided by 16 5 (101): Electrode Oscillator Frequency divided by 32 6 (110): Electrode Oscillator Frequency divided by 64 7 (111): Electrode Oscillator Frequency divided by 128 |
NSCN | Number of Consecutive Scans per Electrode electrode. 0 (00000): Once per electrode 1 (00001): Twice per electrode 2 (00010): 3 times per electrode 3 (00011): 4 times per electrode 4 (00100): 5 times per electrode 5 (00101): 6 times per electrode 6 (00110): 7 times per electrode 7 (00111): 8 times per electrode 8 (01000): 9 times per electrode 9 (01001): 10 times per electrode 10 (01010): 11 times per electrode 11 (01011): 12 times per electrode 12 (01100): 13 times per electrode 13 (01101): 14 times per electrode 14 (01110): 15 times per electrode 15 (01111): 16 times per electrode 16 (10000): 17 times per electrode 17 (10001): 18 times per electrode 18 (10010): 19 times per electrode 19 (10011): 20 times per electrode 20 (10100): 21 times per electrode 21 (10101): 22 times per electrode 22 (10110): 23 times per electrode 23 (10111): 24 times per electrode 24 (11000): 25 times per electrode 25 (11001): 26 times per electrode 26 (11010): 27 times per electrode 27 (11011): 28 times per electrode 28 (11100): 29 times per electrode 29 (11101): 30 times per electrode 30 (11110): 31 times per electrode 31 (11111): 32 times per electrode |
RESERVED | no description available |